Current (amps) = load in watts ÷ 230 V. For PVC-insulated copper house wire in conduit, a common guide is 1.5 sq mm for lighting and fan circuits (10 A MCB), 2.5 sq mm for plug points (16 A), 4 sq mm for ACs and geysers (20–25 A) and 6 sq mm for main lines (32 A). A 1.5 ton AC drawing about 2,000 W needs roughly 9 A, so a 4 sq mm wire on a 20 A MCB is typical. Always have wiring done by a licensed electrician.
| Circuit | Copper wire (PVC, in conduit) | Typical MCB |
|---|---|---|
| Lighting / fan circuit | 1.5 sq mm | 10 A MCB |
| Plug points (5–16 A sockets) | 2.5 sq mm | 16 A MCB |
| AC / geyser / heavy appliance | 4 sq mm | 20 A MCB |
| Main line / large AC | 6 sq mm | 32 A MCB |
These are typical figures for Indian homes. Check the product spec sheet, and ask an electrician or installer before you buy or fit anything.